Manejo Microbiológico dos Grânulos de Polímero Acrílico Usados na Prevenção da Dengue/Microbiological Management of Polymer Granule Acrylic Used in the Prevention of Dengue Fever

Conteúdo do artigo principal

Dante Togeiro Bastos Filgueiras
José Marcos dos Reis

Resumo

RESUMO       

Objetivos: Efetuar o manejo microbiológico dos grânulos de polímero acrílico usados na prevenção da Dengue. Materiais e Métodos: Para a determinação da presença ou ausência de coliformes totais e fecais, e de E. coli, foram realizadas avaliações utilizando metodologia do kit Colitest®. Foram elaborados cinco recipientes com mudas de planta simulando as condições naturais de vasos de polímero acrílico. Utilizaram-se cinco diferentes grânulos de polímero acrílico adquiridos comercialmente. De tais recipientes foram colhidas sete amostras em dias sucessivos. A leitura foi feita com auxílio de uma lâmpada de ondas longas de 365nm, após realizou-se prova de Indol. Resultado: Em relação ao grupo amostragem, em 11,5% não houve crescimento bacteriano, em 17,2% houve presença de E.coli e em 71,3% coliformes totais, constatando altos índices de contaminação. Discussão: Não há na literatura científica trabalhos semelhantes, porém trabalhos analisando águas de outras fontes evidenciam que a água proveniente dos vasos dos grânulos tem maior potencial de contaminação.  Conclusão: Os resultados obtidos permitiram identificar altas taxas de crescimento bacteriano, evidenciando grande risco de contaminação. As informações oferecidas nos rótulos não se encontram nos padrões estabelecidos pela ANVISA. O estudo é de grande importância por efetuar controle de qualidade microbiológico visando à segurança do consumidor em um produto usado na profilaxia do dengue.

Palavras chaves: Dengue, Prevenção & controle, Controle da Contaminação da Água.

 

ABSTRACT

Objectives: To make the microbiological management of acrylic polymer granule used in the prevention of Dengue fever. Materials and Methods: For the determination of the presence or absence of total and faecal coliform and E. coli, evaluations were performed with the use of the kit Colitest® methodology. Five vases were prepared to plant seedlings simulating the natural conditions of acrylic polymer vases. Five different acrylic polymer granule acquired commercially were used. In such containers seven samples were taken on successive days. The reading was done with the aid of a  Long wave 365nm light bulb after which there was the proof of Indole. Results: Regarding the sample group, 11.5% had no bacterial growth,  17.2% showed the presence of E.coli and there was total coliform in 71.3%, finding high levels of contamination. Discussion: No similar studies were found  in the literature, but studies analyzing water from other sources show that water from the vases of the granules has greater potencial contamination. Conclusion: The results have identified high rates of bacterial growth, showing great risk of contamination. The information provided on the labels are not the standards set by ANVISA. The study is of great importance for the making of microbiological quality control aiming at consumer safety in a product used in the prevention of the dengue fever.

Keywords: Dengue fever, prevention & control, Water Contamination Control.



Detalhes do artigo

Como Citar
1.
Filgueiras DTB, Reis JM dos. Manejo Microbiológico dos Grânulos de Polímero Acrílico Usados na Prevenção da Dengue/Microbiological Management of Polymer Granule Acrylic Used in the Prevention of Dengue Fever. HSJ [Internet]. 30º de junho de 2015 [citado 22º de novembro de 2024];5(2):122-9. Disponível em: https://portalrcs.hcitajuba.org.br/index.php/rcsfmit_zero/article/view/340
Seção
ARTIGO ORIGINAL
Biografia do Autor

Dante Togeiro Bastos Filgueiras, Faculdade de Medicina de Itajubá – MG

Acadêmicos do Programa de Desenvolvimento de Iniciação Científica do 5º ano do Curso de Medicina da Faculdade de Medicina de Itajubá (FMIt/MG)

José Marcos dos Reis, Faculdade de Medicina de Itajubá – MG

Médico. Doutor em Medicina. Professor Titular da disciplina de Anatomia Humana da Faculdade de Medicina de Itajubá (FMIt/MG)